Trans-Guard FX |
|
Full-Range Type Current-Limiting |
|
Fuses for Distribution Equipment Protection |
|
General: |
|
The Trans-Guard FX full-range current-limiting fuse provides both overload and short circuit |
|
protection with a single fuse. The Trans-Guard FX line can be installed in "Dry-Well" canisters for |
|
distribution transformer protection, in clip mounts on live-front transformer and switchgear |
|
equipment, and either on or adjacent to equipment on overhead distribution systems. These fuses |
|
can also be installed directly submerged in oil, or they can be encapsulated in rubber for "dead- |
|
front" mounting. |
|
Design Features: |
||
|
|
ü |
High fault current interrupting capability (50,000 amperes symmetrical) |
|
|
ü |
Broad range of ratings available, compatible with existing industry standard sizes and |
|
|
|
mountings |
|
|
ü |
Patented Damage SensorÒ designed to significantly reduce the risk of fuse failure |
|
|
|
should the fuse be subjected to an element damaging current surge |
|
|
ü |
Hermetically sealed construction ensures that no gases escape from the fuse during |
|
|
current interruption and that a fuse's performance will not be adversely affected in dry- |
|
|
|
well canister applications, should the canister develop an oil leak. All Trans-Guard FX |
|
| fuses are helium mass spectrometer leak tested to ensure sealing system integrity. | ||
|
New! |
ü |
Optional blown fuse indicator provides reliable indication of fuse operation without |
|
|
adversely affecting the fuse's arcing performance due to its unique design |
|
|
ü |
Rugged machined brass end caps used for greater ferrule strength, resulting in less |
|
|
|
distortion and more secure fuse attachment in dry-well canisters |
|
|
ü |
Tested in accordance with the most recent ANSI/IEEE standards, which include |
|
|
|
requirements for short circuit testing at the manufacturer's specified rated maximum |
|
|
|
application temperature (140°C and 71°C for 2.2 inch and 3.3 inch diameter |
|
|
|
Trans-Guard FX designs, respectively. |
|
|
Ratings Available: |
|
Trans-Guard FX Fuse Line |
|
|
5.5kV |
80A to 200A in a single 3" dia. body |
|
8.3kV |
3A to 50A in a single 2" dia. body (65A to 100A by paralleling) |
|
65A to 125A in a single 3" dia. body (130A to 250A by paralleling) |
|
|
15.5kV |
3A to 50A in a single 2" dia. body (65A to 100A by paralleling) |
|
65A to 100A in a single 3" dia. body (130A to 200A by paralleling) |
|
|
23.0kV |
6A to 50A in a single 2" dia. body |
|
Brochure: |
|
This downloadable brochure contains electrical characteristic, coordination, dimensional, |
|
and ordering information for the FX product line. |
|
Version: June 2003 172KB |
|
Time Current Characteristic Curves: |
|
These downloadable curves are printable on 8 1/2" x 11 1/2" paper. For full-size 11" x 17" |
|
transparent curves, please contact the factory. |
|
Adobe® Acrobat® (.pdf) Format |
|
Voltage |
Current Rating |
Minimum Melting Curve Number |
Total Clearing Curve Number |
|
Trans-Guard FX Fuse Line |
|||
|
5.5kV |
80A - 200A |
FC-031 (2/01)-8KB |
FC-078 (2/01)-7KB |
|
8.3kV/15.5kV/23.0kV |
3A - 100A |
FC-035 (11/01)-10KB |
FC-081 (11/01)-8KB |
|
8.3kV |
65A - 125A |
FC-022 (2/01)-8KB |
FC-069 (2/01)-7KB |
|
8.3kV |
130A - 250A |
FC-030 (2/01)-8KB |
FC-077 (2/01)-7KB |
|
15.5kV |
65A - 200A |
FC-034 (6/99)-11KB |
FC-066 (6/99)-9KB |
| Certified Test Reports: |
| This report summarizes the short-circuit tests conducted on the Trans-Guard FX fuse line |
| to demonstrate satisfactory and full compliance with the appropriate IEEE/ANSI fuse standards. |
|
Version: June 2001 97KB |
|
For more detailed information, please contact us at 410-822-9611 |